Back to Transformers Index Home Contact Us

WorldPower Series     UR   cUR   cURus   CE

International Class II Power Transformer
Series: PCL2

Standard Models        Schematics        Dimensions       

WorldPower Series PCL2 Photo
  • Power Rating 2.5VA to 50VA
  • Dielectric strength - 4000VRMS
  • Primaries - Dual primaries (115/230V - 50/60Hz)
  • Secondaries - Single secondaries
  • Class 2 Rating - Inherently or non-inherently limited (see secondary fuse requirements in Standard Models table below)
  • Electrosatic Shield - Not required, dual bobbin
  • Insulation - Class F insulation (155o)
  • Flammability Rating - Bobbin/Shroud UL 94V0
  • Designed to meet Class II
  • CE marked
Transformers are designed to meet Class II. They are inherently or non-inherently limited. Available as chassis mount or Printed Circuit mount.

 
Return to TOP
Schematics

world series schematic dot Indicates Like Polarity
Primaries are designed to be used simultaneously. That is, they must be used either Series or Parallel connected (as one winding). Same applies to secondaries also.

Mechanical Drawings

Return to TOP

WorldPower Series 14P Mechanical Drawings

Dimensions

DIMENSIONS SQPin
Dim.
MTG.DIM. Mtg
Screw
WGT
(VA)
Size
L W H A B C M N P Size Qty.
2.5 1.62"
41.3mm
1.31"
33.3mm
1.12"
28.6mm
0.200"
5.1mm
0.250"
6.4mm
1.000"
25.4mm
0.025"
0.64mm
1.06
26.9mm
-
-
-
-
#4 2 0.25lbs
0.11kg
5.0 1.62"
41.3mm
1.31"
33.3mm
1.37"
34.9mm
0.200"
5.1mm
0.400"
10.2mm
1.000"
25.4mm
0.025"
0.64mm
1.06
26.9mm
-
-
-
-
#4 2 0.37lbs
0.17kg
10.0 1.87"
47.6mm
1.56"
39.7mm
1.37"
34.9mm
0.200"
5.1mm
0.400"
10.2mm
1.140"
29.0mm
0.038"
0.97mm
1.25
31.8mm
-
-
-
-
#4 2 0.53lbs
0.24kg
20.0 2.25"
57.2mm
1.87"
47.6mm
1.62"
41.3mm
0.400"
10.2mm
0.400"
10.2mm
1.460"
37.1mm
0.038"
0.97mm
1.50
38.1mm
-
-
-
-
#4 2 0.90lbs
0.41kg
30.0 2.62"
66.7mm
2.18"
55.5mm
1.56"
39.7mm
0.550"
13.9mm
0.275"
7.0mm
1.680"
42.7mm
0.405"
1.14mm
-
-
1.75
44.4mm
2.18
55.5mm
#6 4 1.15lbs
0.52kg
50.0 3.00"
76.2mm
2.50"
63.5mm
1.81"
46.0mm
0.600"
15.2mm
0.300"
7.6mm
1.900"
48.3mm
0.405"
1.14mm
-
-
2.00"
50.8mm
2.50
60.35mm
#6 4 1.70lbs
0.77kg

 
Return to TOP
Standard Models

Part Number Secondary
RMS Rating
Secondery
Fuse Reqd.
PCL2-2.5-12 12V @ .20A N/A*
PCL2-2.5-24 24V @ .10A N/A*
PCL2-5.0-12 12V @ .42A N/A*
PCL2-5.0-24 24V @ .20A N/A*
PCL2-10-12 12V @ .83A N/A*
PCL2-10-24 24V @ .42A N/A*
PCL2-20-12 12V @ 1.66A N/A*
PCL2-20-24 24V @ .833A N/A*
PCL2-30-12 12V @ 2.50A 3.0A**
PCL2-30-24 24V @ 1.25A N/A*
PCL2-50-12 12V @ 4.20A 5.0A**
PCL2-50-24 24V @ 2.10A 2.5A**
*   Inherently Limited
**  Non-inherently Limited
    Maximum secondary fuse value specified
    All primaries are 115/230 volt 50/60 Hz
Ask for specials. Use our on-line custom transformer design form or contact us.
Custom variations are quoted and shipped promptly.
About Us Products What's New RFQ Tech.
Assistance
Ordering Info. Cross
Reference
Reps. Distributors Contact Us Site
Map

We continually improve our products, therefore specifications are subject to change without notice. PowerVolt does not assume liability arrising out of use or misuse of any product. PowerVolt does not recommend the use of its products in applications wherin a failure or malfunction may directly threaten life or cause human injury. The user of PowerVolt products assumes all risk of such use and indemnifies PowerVolt against all damages.

Return to TOP
© 2004 PowerVolt, Inc. All rights reserved.